Moisture testers, Paper

HK-300

HK-300

This paper moisture sensor can measure the moisture content of a variety of paper types, such as craft paper, liner board, copy paper and cardboard. The HK-300 series comes in three sets with different sensor types to accommodate the type of paper to be measured and the application: the HK- 300-1 set includes a grip sensor, the HK-300-2 set includes an electrically conductive rubber sensor, and the HK-300-3 set includes a constant pressure sensor.

Applications: Craft paper, Liner board, Copy paper, Cardboard, etc.
Measurement method: Electrical Resistance Method
Product downloads: HK-300 series manual
Product type: Paper, Moisture testers
Accuracy: Standard error 0.4 % (at 15 % moisture or less)
Calibration curve: Craft paper, Liner board, Copy paper, Cardboard, etc.
Display: Digital (LCD, smallest displayed unit 0.1%)
Measurement range: Grip sensor: Copy paper 4-15 %, Cardboard 6-20 %. Conductive rubber sensor: Copy paper 4-25 %, Liner board 6-23 %, Kraft paper 5-24 %. Constant pressure sensor: Copy paper 2-10 %, Liner board 5-15 %, Kraft paper 2-10 %
Accessories supplied: Carrying case, Shoulder strap, 6 x 1.5 V batteries (AA size Alkaline)
Options: Printer (VZ-330), Printer cable (VZC-26)
Power supply: 6 x 1.5 V Batteries (AA size Alkaline)
Power consumption: Approx. 0.45 W
Dimensions: 110 (W) x 210 (D) x 50 (H) mm
Weight: 0.5 kg

Concrete and mortar, Moisture testers

HI-800

HI-800

The HI-800 Concrete & Mortar Moisture Tester has been designed to enable measurement of moisture at depths of up to 150mm. This unit is used to determine moisture in applications such as injection of epoxy resins into Concrete for fixing of Mortar or Tiles. If moisture is too high where the epoxy is injected, adhesion will be unsatisfactory.

Applications: Concrete, Mortar
Measurement depth: Up to 50 mm from the surface (up to 150 mm using optional equipment)
Measurement method: Electrical Resistance Method
Product type: Concrete and mortar
Display format: Digital (LCD, smallest displayed unit 0.1%, RH 0.1 °C)
Measurement range: Concrete: 0-10%, Mortar: 0-15%
Temperature correction: Automatic or Manual Temperature Correction
Power supply: 4 x 1.5 V Batteries (AA size Alkaline)
Dimensions: 75 (W) × 145 (D) × 31 (H) mm
Weight: 1 kg

Concrete and mortar, Moisture testers

HI-520-2

HI-520-2

The HI-520-2 concrete and mortar moisture tester can measure moisture contents by simply placing the moisture sensor against objects to be measured thanks to the introduction of high-frequency capacitance method for measurement. In addition to the functions of the conventional type, HI-520 , which has been widely used in the industry, this product has an enlarged screen with embedded backlight, and ergonomically redesigned housing and switches, i.e. HI-520-2 has become a more user-friendly instrument.

Applications: Concrete, Mortar, ALC, Artificial lightweight aggregate concrete, Gypsum board, Calcium silicate board
Functions: Temperature correction, backlight, upper limit of moisture content alarm setting, hold, user calibrations (8 pcs.)
Measurement method: High frequency capacitance
Product downloads: HI-520-2 brochure, HI-520-2 manual
Product type: Moisture testers, Concrete and mortar
Accuracy: ± 0.5% (Concrete, Mortar)
Display: Digital (LCD, smallest displayed unit 0.1%)
Measurement range: Concrete: 0-12%, Mortar: 0-15%, ALC: 0-100%, Artificial Lightweight aggregate concrete: 0-23%, Gypsum board: 0-50%, Calcium silicate board: 0-15%, D mode:0-1999, S mode: 0-1100
Accessories supplied: 9 V alkaline battery (006P), soft case (with strap), operating manual
Options: Data logger software, HDL-01 (with USB cable)
Power supply: 9 V (006P Alkaline battery)
Dimensions: 72 (W) × 150 (D) × 120 (H) mm
Weight: 0.39 kg

Concrete and mortar

HI-330

HI-300

With the HI-330, you can easily find the moisture content and single unit water volume on-site by simply placing the weight-screened mortar (or sand) into the sample tray and pressing the measurement key. You can even send the control data information to a printer. Furthermore, in addition to measuring the moisture content of mortar, the HI-330 can also measure the surface water ratio of fine aggregates.

Applications: Mortar (things that have been weight-screened by wet Concrete) Fine aggregates
Functions: Individual moisture mass estimate, Cement composition estimate (comparing water vs. cement), User scale registration, Combination data registration, Average value, 126 memory slots, 15 minute auto power-off
Measurement method: Capacitance type
Product type: Concrete and mortar
Accuracy: Mortar: ± 0.5% (repeated precision) Aggregates used with the HI-330: ± 0.3% (repeated Precision)
Display: Digital (LCD, smallest displayed unit 0.1%)
Measurement range: Mortar: 20-40% (volume moisture rate), Aggregates: above 15
External communications: RS-232C interface
Accessories supplied: Sample case, Additional connector, Dummy, AC adapter, Carrying case
Options: Printer (VZ-350)
Power supply: 100 V AC (50/60 Hz) or 6 x 1.5 V (AA size Alkaline batteries)
Dimensions: 300 (W) x 264 (D) x 197 (H) mm
Weight: 2.5 kg

Concrete and mortar

HI-300

HI-300

With the HI-300, you can easily find the moisture content and single unit water volume on-site by simply placing the weight-screened mortar into the sample tray and pressing the measurement key. You can even send the control data information to a printer. Furthermore, in addition to measuring the moisture content of mortar.

Applications: Mortar (things that have been weight-screened by wet Concrete)
Functions: Individual moisture mass estimate, Cement composition estimate (comparing water vs. cement), User scale registration, Combination data registration, Average value, 126 memory slots, 15 minute auto power-off
Measurement method: Capacitance type
Product type: Concrete and mortar
Accuracy: Mortar: ± 0.5% (repeated precision) Aggregates used with the HI-330: ± 0.3% (repeated Precision)
Display: Digital (LCD, smallest displayed unit 0.1%)
Measurement range: Mortar: 20-40% (volume moisture rate)
External communications: RS-232C interface, USB (for PC)
Accessories supplied: Sample case, Additional connector, Dummy, AC adapter, Carrying case
Options: Printer (VZ-350)
Power supply: 100 V AC (50/60 Hz) or 6 x 1.5 V (AA size Alkaline batteries)
Dimensions: 300 (W) x 264 (D) x 197 (H) mm
Weight: 2.5 kg

Other

Heidon Tribo gear μ94i

Tribogear 94i

In the past, static friction was typically measured using the incline method and a strain gauge. However, this method poses many difficulties when used in confined spaces such as Laboratories etc. The HEIDON Tribo Gear μ94i is a new portable device, which makes it very easy for anyone to measure the static friction coefficient of objects.

Product downloads: Heidon Tribo gear μ94i manual
Product type: Other instruments
Detector: VCM photosensor
Accuracy: ± 1%
Indicator: LED 7 segments
Measurement range: static friction coefficient 0.001-1.300
Resolution: 0.01-0.001
Power supply: 4 x 1.5 V Batteries (AA size Alkaline)
Dimensions: 188 (W) x 62 (D) x 64 (H) mm
Weight: 0.6 kg

Universal

HB-300

HB-300

The HB-300 Universal Moisture Tester embraces a new concept which enables users to input calibrations easily for their own products.Various optional sensors are available, to facilitate accurate moisture measurement. Applications include solids, powders, granular or tablets, pastes and sheets (which do not include any electrolytic).

Measurement method: Electrical Resistance Method
Product downloads: HB-300 manual
Product type: Universal
Accuracy: Depends on calibration
Measurement range: 1-99% (sample dependent)
Operating environment: 0-40 °C
Options: Printer (VZ-330), sensors
Power supply: 6 x 1.5 V Batteries (AA size Alkaline)
Dimensions: 110 (W) x 210 (D) x 50 (H) mm
Weight: 0.5 kg

Infrared moisture balance

FW-100

FW-100

The FW-100 is a windshield for the FD Series Infrared Moisture Determination Balances. It is fitted with a deodorising function. When an infrared moisture balance is placed within, the FW- 100 reduces the effect of external air currents on the high precision balance. Depending upon the sample type, an unpleasant odour may be emitted during moisture measurement. The deodorizing filter incorporated in the FW-100, reduces any odour.

Product type: Infrared moisture balances
Accessories supplied: Upper Lid (includes shutter, 2 x deodorising filters), 2 x Side panels, Rear panel, Front face metal fixtures
Applicable devices: FD-800, FD-720, FD-620, FD-610, FD-600, FD-240
Replacement parts: Deodorising filter
Dimensions: 333 (W) x 465 (D) x 509 (H) mm
Weight: 5.3 kg

Infrared moisture balance

FM-300A

FM-300A

The FM-300A Micro Moisture Analyzer allows the user to accurately measure samples as low as two parts per million (2ppm). Unlike Karl Fisher Titrators, no chemical reagents are used, therefore only moisture is measured (as chemical interaction is eliminated). The FM-300A eliminates the cost of reagents and preparation necessary for Karl Fisher Titrators, as well as the expensive disposal cost of the various wastes.

Measurement method: Filter Moisture Adsorption
Measurement mode: Time/Automatic measurement
Product type: Infrared moisture balances
Heat source: 400 W EC Heater
Resolution: 0.01 mg/2 ppm (When sample weighs 5 g)
Sample weight: 10 mg-5 g
External communications: RS-232C interface
Options: Printer (VZ-330 w/VZC-14 cable), Data logger software (PDL-01)
Power supply: 100-120 V AC/220-240 V AC (50/60 Hz)
Dimensions: 585 (W) x 520 (D) x 480 (H) mm
Weight: 37.0 kg

Infrared moisture balance

FD-800

FD-800

The FD-800 employs a dual temperature sensing method to achieve highly precise moisture measurements. In addition to the thermistor that measures the environment temperature within the drying chamber, it is mounted with a radiation thermometer that measures the sample temperature directly without contact.

Measured components: Moisture, Solid content, Weight
Measurement method: Detection of weight loss by heating & drying
Measurement mode: Automatic stop mode, Timer stop mode, Rapid drying mode, Equilibrium drying mode, Step drying mode, Predictive (comparative) measurement mode
Product downloads: FD-800 brochure, FD-800 manual
Product type: Infrared moisture balances
Heat source: Mid-wave infrared quartz heater (200 W x 2)
Measurement range: 0-100% (wet base, solid content); 0-500% (dry base)
Resolution: Moisture percentage 0.01% / 0.1%; Weight 1 mg Temperature setting range for thermistor (T1): 30-180 °C (1 °C interval); for radiation thermometer (T2) 30-250 °C (1 °C interval)
Repeatability: Sample with a weight of 5 g or higher : 0.05%; Sample with a weight of 10 g or higher : 0.02%)
Sample pan: Stainless steel (130 mm in diameter, 13 mm in depth)
Sample weight: 0.1-120 g (optional weight sampling)
Operating environment: Temperature 5-40 °C, Humidity max of 85% RH, Pollution degree 2, Altitude up to 2000 m
External communications: RS-232C interface
Accessories supplied: Spare sample pan, Aluminum sheets, etc
Options: Printer Set (VZ-330, Printer Cable: VZC-14) 10x Printer paper rolls, 500x Aluminum sheets Radiation thermometer calibration kit GF-200 (digital thermometer, standard heating sample), Data logger software “FDL-02” (RS-232C cable, USB-RS232C conversion ca
Power supply: 100-120 V AC/220-240 V AC (50/60 Hz)
Power consumption: Max. 900 W
Dimensions: 220 (W) x 415 (D) x 190 (H) mm
Weight: 4.5 kg